The Armored Cable Termination (ACT) Finite Element Analysis (FEA) was performed using SolidWorks Simulation. The maximum load is 10kips (2.2 kN), and the material is ASTM A4140. The highest stress is occuring in the load pin area.
.
.
This ACT Stress Report was created using MapleSoft and traditional stress analysis equations.
.
.